trang chủ
  • Công ty CP SX-XNK HDC
  • Công ty CP SX-XNK HDC
  • Công ty CP SX-XNK HDC
  • Công ty CP SX-XNK HDC
Báo Cháy BOSCH
CARD MỞ RỘNG 4 VÙNG BOSCH FPC-7034
980.000 VNĐ
980.000 VNĐ

CARD MỞ RỘNG 4 VÙNG BOSCH FPC-7034

- Card mở rộng 04 vùng, dùng cho bộ điều khiển báo cháy BOSCH FPD-7024.

- Sử dụng các công tắc cảnh báo thường đóng, thường mở (NC, NO).

- Tương thích với các đầu dò 2 dây hoặc 4 dây.

- Mỗi vùng có thể sử dụng đến 20 đầu dò.

- Lắp đặt dễ dàng và không cần lập trình.

- Adds four Class B (Style B) or two Class A (Style D) initiating circuits to the FPD‑7024 FACP.

- For use with normally‑open (NO) or normally‑closed (NC) alarm contacts.

- Compatible with two‑wire or four‑wire smoke detectors

- Up to 20 two‑wire smoke detectors per circuit

- Easy installation due to plug‑in design and screw terminal circuit connections

- No programming necessary

 

The FPC‑7034 Four-point Expander doubles the number of alarm initiating device circuits on the FPD‑7024 Fire Alarm Control Panel (FACP). These circuits are identical to the circuits on the FACP. This plug‑in module is automatically recognized by the control panel's firmware when power is restored to the system.

 

Specifications

Environment

Indoor, dry

Relative Humidity

Up to 95%, non‑condensing

Temperature (operating)

+32°F to +122°F (0°C to +50°C)

Dimensions (HxWxD)

2.0 in. x 4.5 in. x 1.3 in. (5.1 cm x 11.4 cm x 3.3 cm)

Response Time

Choice of fast (500 ms) or programmable from 1 sec to 89 sec

per initiating circuit

 

Alarm Current (short circuit)

40 mA maximum

Alarm Current (threshold)

>25 mA

Detector Standby Current (total)

3 mA maximum

Loop Supervision Current

8.0 mA to 15.0 mA

Trouble Current Threshold

 

Voltage (supply)

18.0 VDC to 25.5 VDC

Current (standby)

60 mA maximum

Current (alarm)

160 mA maximum

- Bảo hành: 12 tháng.

Bộ mở rộng 4-ngõ ra điều khiển chuông tích hợp nguồn 24VDC-8A BOSCH FPP-RNAC-8A-4C
8.494.200 VNĐ
8.494.200 VNĐ

Bộ mở rộng 4-ngõ ra điều khiển chuông tích hợp nguồn 24VDC-8A BOSCH FPP-RNAC-8A-4C

-       Bộ mở rộng 4-ngõ ra điều khiển chuông và tích hợp nguồn 24VDC/8A.

-       FPP‑RNAC‑8A‑4C Remote Notification Appliance Circuit (RNAC) Power Supply 8A of power.

-       Fully supervised outputs

-       Configurable for NAC output or constant auxiliary power

-       Regulated 24 VDC output (nominal) with over‑current protection

-       Built‑in NAC patterns

 

Use the FPP‑RNAC‑8A‑4C power supply to add four additional notification appliance circuits to a fire alarm control panel (when connected via the option bus), or as a NAC power supply for fire-protective signaling systems (when connected directly to the NAC output).

The additional notification appliance circuits can beNFPA 72, Class B (Style Y) or Class A (Style Z). This regulated power supply provides up to 8 A of power that is used to operate both continuous and intermittent loads. This 8 A of power can be distributed through the four output circuits and auxiliary power circuit. The FPP‑RNAC‑8A‑4C power supply is UL Listed for use in commercial fire alarm applications.

 

Compatible Control Panel Connections

-       The FPP‑RNAC‑8A‑4C power supply is compatible with any UL Listed control panel that uses reverse polarity supervised notification outputs with 12 VDC or 24 VDC regulated outputs.

-       FPD‑7024 or FPA‑1000 Analog Addressable Fire Panels: Connect up to four FPP‑RNAC‑8A‑4C power supplies to an FPD‑7024 or an FPA‑1000 control panel.

 

Specifications

Temperature (operating)

+32°F to +120°F (0°C to +49°C)

Response Time (input to output)

10 ms maximum

Color

Red

Dimensions (HxWxD)without door

20.4 in. x 14.8 in. x 4.1 in. (52 cm x 38 cm x 10.4 cm)

Material

cold-rolled steelBase: 18 gauge (1.2 mm)Cover: 19 gauge (1.1 mm)

Current (output)

850 mA maximum

Voltage (output)

24 VDC (regulated)

Output per circuit

2.5 A maximum

Output (total)

8 A (all NAC and auxiliary outputs)

Voltage (output)

24 VDC (regulated)

Voltage (standby)

-24 VDC (regulated)

Compatibility range

19.6 VDC to 27.5 VDC

Current (output)

1.3 A maximum

Voltage (output)

24 VDC nominal

Voltage (ripple)

250 mVp-p

Contact Type

Form C

Rating (contact)

1.5 A at 32 VDC

Current (input)

4.5 A maximum (RMS)

Power (primary input)

120 VAC, 60 Hz or 220 VAC, 50 Hz

Voltage (battery)

24 VDC nominal

-       Bảo hành: 12 tháng.

BỘ ĐIỀU KHIỂN BÁO CHÁY TRUNG TÂM BOSCH FPD-7024
7.613.000 VNĐ
7.613.000 VNĐ

BỘ ĐIỀU KHIỂN BÁO CHÁY TRUNG TÂM BOSCH FPD-7024

-       Tủ điều khiển báo cháy 4 vùng, có thể mở rộng lên 8 vùng. Mỗi vùng có thể sử dụng đến 20 đầu dò.

-       Tương thích với các đầu dò 2 dây.

-       Có thể cài đặt, lập trình thông qua giao diện phía trước hoặc bàn phím FMR-7033 hoặc lập trình từ xa với phần mềm RPS và giao tiếp nối tiếp DX4010V2.

-       Có thể mở rộng lập trình hay xem báo cáo từ xa với các card giao tiếp mạng IP Ethernet (DX4020, ITS-DX4020-G, B420, B426 hoặc B450/B44x).

-       02 mạch thiết bị thông báo NAC.

-       Sản phẩm đạt các Chứng nhận của Mỹ: UL, FM, CSFM, FCC, FDNY-CoA.

 

FPD‑7024 Fire Alarm Control Panels

-       The FPD‑7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems.

-       The FPD‑7024 FACPs support four on‑board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two‑wire and four‑wire detectors configurable as Class A , Style D or Class B, Style B loops. Each zone can support up to 20 two‑wire detectors, or any number of four‑wire detectors depending on available power. Each FACP has a built‑in digital fire alarm communicator transmitter (DACT).

-       Enhance the FPD‑7024 conventional system features by adding a D7039 Multiplex Expansion Module.

-       Adding a D7039 Multiplex Expansion Module to the FPD‑7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100.

-       Four initiating zones (expandable to eight); up to 20 two‑wire smoke detectors per zone

-       Programmable through front panel interface, remote FMR‑7033 Liquid‑crystal Display (LCD) keypads, or remote programming software (RPS) through a DX4010V2 serial interface

-       Expandable for programming or reporting with Ethernet or cellular IP connectors (DX4020, ITS-DX4020-G, B420, B426, or B450/B44x)

-       Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply

-       Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module

 

Functions

Notification Appliance Circuits (NACs)

Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for Wheelock, Gentex, or System Sensor notification appliances.

 

User Interface

A viewing port in the locked control panel enclosure door shows the system status light‑emitting diodes (LEDs) and liquid‑crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off‑normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR‑7033 LCD Keypads connected to the system.

 

Organized Event Display

Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific

events.

 

History Buffer

The system stores events in a 99‑event history buffer (The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module.)

 

Central Station Reporting

The FPD-7024 FACPs send reports to two telephone numbers (or IP addresses with a DX4020/B420/B426 Network Interface Module installed) with full single, double, and backup reporting. The panel supports communication in BFSK, SIA, Contact ID, Modem IIIa2, and 4/2 or 3/1 Tone Bursts.

 

Dirty Smoke Detector Monitoring

All on‑board zones and FPC‑7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two‑wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head.

 

Specifications

Current (alarm)

380 mA

Current (standby)

200 mA

Power (primary)

120 VAC , 1.2 A maximum, 60 Hz or240 VAC , 0.75 A maximum, 50 Hz

Environment

Indoor, dry

Relative Humidity

Up to 95%, non-condensing

Temperature (operating)

+32°F (0°C) to +120°F ( +49°C)

Color

Red

Dimensions (HxWxD)

20.8 in. x 15 in. x 4.3 in. (52.8 cm x 38.1 cm x 10.9 cm)

Material

Cold-rolled steelBase: 18 gauge (1.2 mm)Cover: 19 gauge (1.1 mm)

Current

44 mA maximum per loop

Line resistance

150 Ω

Voltage

24 VDC nominal

NAC

24 VDC nominal, 4 A maximum

On-board Relays

Three Form C contacts rated at 5 A, 28 VDC

Off-board Relays

Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus for a total of 40

-       Bảo hành: 12 tháng.

Thông tin công ty
LIÊN HỆ VỚI CHÚNG TÔI
bán hàng tư vấn kỹ thuật
  • Tư vấn trực tuyến
    0932 113 055
  • Tư vấn và giải quyết KM
    0933 329 123
TELL: 08- 62644132  -   HOTLINE: 0909 411 988  -   EMAIL: dathdcvn@gmail.com Facebook Twitter Google+ Addthis
top